WX-SNC-1200 Submerged Arc Furnace Short-Network Compensation Controller
+
  • WX-SNC-1200 Submerged Arc Furnace Short-Network Compensation Controller

WX-SNC-1200 Submerged Arc Furnace Short-Network Compensation Controller


High integration design with bus-free architecture


  • Core Advantages
  • Technical Parameter
  • 1. Features a high integration design with bus-free architecture.
    2. All-in-One Controller: Combines control, measurement, and protection functions, including multi-stage overcurrent protection, overvoltage/undervoltage protection, over-temperature alarms, thermal failure detection, and refusal-to-operate monitoring.
    3. Offers customizable configuration to adapt to various cabinet layouts on-site.
    4. Integrated with a large-current acquisition port and Rogowski coils—offering linear response, saturation-free performance, and simple calibration—for accurate electrode signal measurement.
    5. Delivers outstanding transient response, suitable for medium- and high-voltage protection scenarios.
    6. Entire signal input path is free from secondary open-circuit risks.
    7. Fully enclosed chassis, strict separation of power and signal wiring, strong electromagnetic immunity, full hardware self-diagnostics, and excellent stability in harsh environments.

  • The control system calculates the active power, reactive power, and power factor by collecting the three-phase voltage and current at both the high and low voltage sides. It comprehensively considers voltage fluctuations and reactive power shortages and reasonably controls the switching of the capacitor bank using a three-phase unbalance adjustment strategy. This ensures the supply and demand balance of reactive power in the submerged arc furnace short-circuit network, thereby improving supply voltage quality, power factor, system efficiency, and reducing system loss. Control parameters can be chosen from either the high voltage side's voltage and current or the low voltage side's voltage and current. The system protection functions include high voltage side overvoltage and undervoltage protection, low voltage side overvoltage and undervoltage protection, as well as overcurrent, unbalanced current, high power factor, harmonic, temperature, and circulating water protection functions.

Keywords:

WX-SNC-1200 Submerged Arc Furnace Short-Network Compensation Controller

File Download

  • File size: 68.8MB

Online Inquiry

Note: Please leave your phone number or email address, our professionals will contact you as soon as possible!

Online Inquiry

We will contact you within one working day. Please pay attention to your email.

Submit